Diagnostique des HBA
par
popularité : 2%
Connaître l’état de santé des cartes HBA de votre serveur Oracle/Sun :
Il est possible d’utilisé au moins deux commandes :
- fcinfo hba-port -l
- luxadm :
for CTRL in $(luxadm -e port |cut -d ’ ’ -f1 )
do
echo "######"
echo $CTRL
luxadm -e rdls $CTRL
done
Exemple :
# fcinfo hba-port -l
HBA Port WWN : 2100001b32131fb4
OS Device Name : /dev/cfg/c4
Manufacturer : QLogic Corp.
Model : 375-3356-02
Firmware Version : 4.04.01
FCode/BIOS Version : BIOS : 1.24 ; fcode : 1.24 ; EFI : 1.8 ;
Serial Number : 0402R00-0821533940
Driver Name : qlc
Driver Version : 20080617-2.29
Type : N-port
State : online
Supported Speeds : 1Gb 2Gb 4Gb
Current Speed : 2Gb
Node WWN : 2000001b32131fb4
Link Error Statistics :
Link Failure Count : 1
Loss of Sync Count : 0
Loss of Signal Count : 0
Primitive Seq Protocol Error Count : 0
Invalid Tx Word Count : 754974720
Invalid CRC Count : 16
HBA Port WWN : 2101001b32331fb4
OS Device Name : /dev/cfg/c5
Manufacturer : QLogic Corp.
Model : 375-3356-02
Firmware Version : 4.04.01
FCode/BIOS Version : BIOS : 1.24 ; fcode : 1.24 ; EFI : 1.8 ;
Serial Number : 0402R00-0821533940
Driver Name : qlc
Driver Version : 20080617-2.29
Type : N-port
State : online
Supported Speeds : 1Gb 2Gb 4Gb
Current Speed : 2Gb
Node WWN : 2001001b32331fb4
Link Error Statistics :
Link Failure Count : 1
Loss of Sync Count : 0
Loss of Signal Count : 0
Primitive Seq Protocol Error Count : 0
Invalid Tx Word Count : 0
Invalid CRC Count : 0
# for var in $(luxadm -e port |cut -d ’ ’ -f1 ) ; do echo "######" ; echo $var ;luxadm -e rdls $var ; done
######
/devices/pci@3,700000/SUNW,qlc@0/fp@0,0:devctl
Link Error Status information for loop :
al_pa lnk fail sync loss signal loss sequence err invalid word CRC
666913 0 0 0 0 0 0
666213 1 0 0 0 805306368 18
NOTE : These LESB counts are not cleared by a reset, only power cycles.
These counts must be compared to previously read counts.
######
/devices/pci@13,700000/SUNW,qlc@0/fp@0,0:devctl
Link Error Status information for loop :
al_pa lnk fail sync loss signal loss sequence err invalid word CRC
661d13 0 0 0 0 0 0
666e13 0 0 0 0 0 0
661e13 1 0 0 0 0 0
NOTE : These LESB counts are not cleared by a reset, only power cycles.
These counts must be compared to previously read counts.